Ground Fault Solid-Core Current Transformer
The AcuCT G Series Ground Fault Solid-Core CT is a residual current sensor that detects earth leakage in a power distribution system. All live conductors pass through the single window, and the CT measures the residual current, which is the vector sum of those currents. This value sits near zero in a healthy circuit and rises when leakage occurs, helping identify ground faults, insulation degradation and leakage between 10 mA and 10A. The sensor outputs a proportional mA signal to a connected meter or residual current monitor, which applies the alarm and trip thresholds. The enclosure design is suitable for indoor and protected outdoor installation under various environmental conditions.
- 5% accuracy from 1 to 120% of rated residual current for ground fault (earth leakage) detection
- Large window accepts all phase and neutral conductors for core-balance measurement
- Short-Time Thermal Current (STTC) rated at 15 kA for 1 second
- Surge rated current can withstand 50 kA/50ms
- Secondary overvoltage suppression for durability
- Installation ready with solid-core form factor and screw-type terminal
| NAME | CATEGORY | |
|---|---|---|
| Product Datasheet | Download PDF |
| NAME | ||
|---|---|---|
| Current Transformers in Medium Voltage (MV) Systems | White Paper |
About AcuCT G Series Models
Current Transformers for Ground Fault Detection
Ground fault current transformers are designed for ground fault and leakage current detection in power distribution systems. With a transformation ratio of 600: 1 and an accuracy of 5%, it provides an mA output proportional to the input range for residual current monitors. Rated to withstand a short-time thermal current of 15 kA for 1 second and a surge current of 50 kA for 50 ms, it ensures reliable performance under fault conditions.
AcuCT G Models
AcuCT-5913G-SC | Primary Current | Output | Accuracy | Window Size |
|---|---|---|---|---|
| 10 mA - 10A | mA Proportional to Primary Current | 5% | 13.86" × 5.98" |
AcuCT-5913G-SC |
|---|
|
Primary Current | Output | Accuracy | Window Size |
|---|---|---|---|
| 10 mA - 10A | mA Proportional to Primary Current | 5% | 13.86" × 5.98" |
AcuCT-7919G-SC | Primary Current | Output | Accuracy | Window Size |
|---|---|---|---|---|
| 10 mA - 10A | mA Proportional to Primary Current | 5% | 7.953" × 19.764" |
AcuCT-7919G-SC |
|---|
|
Primary Current | Output | Accuracy | Window Size |
|---|---|---|---|
| 10 mA - 10A | mA Proportional to Primary Current | 5% | 7.953" × 19.764" |