Rogowski Coils

Custom designed and built in-house, our high accuracy industrial grade flexible current transformers are made with the highest specification at exceptional value.

Rogowski Coils Comparison

AcuCT Flex Series

High Accurancy Flexible CT

AcuCT Flex Series of Rogowski Current Transformers
RIK 5A

5A Rogowski Integrator Kit

AcuCT Flex Series of Rogowski Current Transformers
RIK mV

333mV Rogowski Integrator Kit

AcuCT Flex Series of Rogowski Current Transformers
RIK 4-20 mA

4-20mA or 0-20mA Rogowski Integrator Kit

AcuCT Flex Series of Rogowski Current Transformers
RIK 0-5V

0-5V / 0-10V Rogowski Integrator Kit

AcuCT Flex Series of Rogowski Current Transformers
LocationPanel / Device / Circuit / BusPanel / Device / Circuit / BusPanel / Device / Circuit / BusPanel / Device / Circuit / BusPanel / Device / Circuit / Bus
Form FactorFlexible Rope-Like CTFlexible Rope-Like CTFlexible Rope-Like CTFlexible Rope-Like CTFlexible Rope-Like CT
ApplicationHigh Accurancy Power Quality Tenant Metering Tight SpacesHigh Accurancy Power Quality Tenant Metering Tight SpacesHigh Accurancy Power Quality Tenant Metering Tight SpacesHigh Accurancy Power Quality Tenant Metering Tight SpacesHigh Accurancy Power Quality Tenant Metering Tight Spaces
Input Rated Option1-50kA500A, 1000A, 2500A, 5000A, 10000A, 25000A and 50000A500A, 1000A, 2500A, 5000A, 10000A, 25000A and 50000A500A, 1000A, 2500A, 5000A, 10000A, 25000A and 50000A500A, 1000A, 2500A, 5000A, 10000A, 25000A and 50000A
Output Rated OptionsmV0 – 6A RMS (0 – 5A RMS Nominal)0-333mVac4-20mAdc, 0-20mAdc0-5Vdc, 0-10Vdc
Measurement Range50,000A2.5A – 60000A2.5A – 60000A2.5A – 60000A2.5A – 60000A
Accuracy0.5%1%1%1%1%
Min. Window Size (in)4.174.174.174.174.17
Max. Window Size (in)14.514.514.514.514.5
UL Listed
CE
UL Recognized
RoHS
AcuCT Flex Series

High Accurancy Flexible CT

AcuCT Flex Series of Rogowski Current Transformers
LocationPanel / Device / Circuit / Bus
Form FactorFlexible Rope-Like CT
ApplicationHigh Accurancy Power Quality Tenant Metering Tight Spaces
Input Rated Options1-50kA
Output Rated OptionsmV
Measurement Range50,000A
Accuracy0.5%
Min. Window Size (in)4.17
Max. Window Size (in)14.5
CE
UL Recognize
RoHS
RIK 5A

5A Rogowski Integrator Kit

AcuCT Flex Series of Rogowski Current Transformers
LocationPanel / Device / Circuit / Bus
Form FactorFlexible Rope-Like CT
ApplicationHigh Accurancy Power Quality Tenant Metering Tight Spaces
Input Rated Options500A, 1000A, 2500A, 5000A, 10000A, 25000A and 50000A
Output Rated Options0 – 6A RMS (0 – 5A RMS Nominal)
Measurement Range2.5A – 60000A
Accuracy1%
Min. Window Size (in)4.17
Max. Window Size (in)14.5
UL Listed
CE
RoHS
RIK mV

333mV Rogowski Integrator Kit

AcuCT Flex Series of Rogowski Current Transformers
LocationPanel / Device / Circuit / Bus
Form FactorFlexible Rope-Like CT
ApplicationHigh Accurancy Power Quality Tenant Metering Tight Spaces
Input Rated Options500A, 1000A, 2500A, 5000A, 10000A, 25000A and 50000A
Output Rated Options0-333mVac
Measurement Range2.5A – 60000A
Accuracy1%
Min. Window Size (in)4.17
Max. Window Size (in)14.5
UL Listed
CE
RoHS
RIK 4-20 mA

4-20mA or 0-20mA Rogowski Integrator Kit

AcuCT Flex Series of Rogowski Current Transformers
LocationPanel / Device / Circuit / Bus
Form FactorFlexible Rope-Like CT
ApplicationHigh Accurancy Power Quality Tenant Metering Tight Spaces
Input Rated Options500A, 1000A, 2500A, 5000A, 10000A, 25000A and 50000A
Output Rated Options4-20mAdc, 0-20mAdc
Measurement Range2.5A – 60000A
Accuracy1%
Min. Window Size (in)4.17
Max. Window Size (in)14.5
UL Listed
CE
RoHS
RIK 0-5V

0-5V / 0-10V Rogowski Integrator Kit

AcuCT Flex Series of Rogowski Current Transformers
LocationPanel / Device / Circuit / Bus
Form FactorFlexible Rope-Like CT
ApplicationHigh Accurancy Power Quality Tenant Metering Tight Spaces
Input Rated Options500A, 1000A, 2500A, 5000A, 10000A, 25000A and 50000A
Output Rated Options0-5Vdc, 0-10Vdc
Measurement Range2.5A – 60000A
Accuracy1%
Min. Window Size (in)4.17
Max. Window Size (in)14.5
UL Listed
CE
RoHS